Heating, ventilation & energy · UK estimating guide

How to price heat recovery ventilation installation work

Plan a UK heat recovery ventilation installation estimate with measured scope, product choices and exclusions. Review 7 fictional GBP lines and the matching £9,143.28 PDF example.

THE ESTIMATING ANSWER

Estimate heat recovery ventilation installation by measuring the defined one small dwelling ventilation unit, separating product allowances from labour and setting out the work sequence and exclusions. This fictional Oxford example uses 7 itemised lines totalling £9,143.28; its exact quantities and rates appear in the paired app PDF.

The worked job is one small dwelling ventilation unit in Oxford. The written scope is: Install a selected heat-recovery ventilation unit with defined supply and extract points in an accessible area, subject to system design. Its matching itemised example shows how that description becomes quantities, allowances and a PDF. These figures are fictional inputs for learning the method, so check the real site, specification and supplier or subcontractor costs before quoting.

1. Define the measured job

Install a selected heat-recovery ventilation unit with defined supply and extract points in an accessible area, subject to system design. Count terminals, measure duct routes and available plant space, and record condensate and power needs. Record the measurements and existing condition in the estimate before turning quantities into line items. The scope should make clear why this is a separate project from a broader renovation or maintenance quote.

Measure for this job: Count terminals, measure duct routes and available plant space, and record condensate and power needs. Record the measured basis next to the relevant cost lines, since a room count, fitted length and purchased product quantity may each use a different unit.

2. Build a product and labour schedule

Separate unit, duct, terminals and controls from commissioning. This example has 7 distinct lines, including ventilation design allowance, hrv unit allowance, duct and insulation allowance. Use actual supplier prices and labour inputs for a customer job; the displayed amounts are fictional document inputs.

Choose before pricing: Separate unit, duct, terminals and controls from commissioning. Keep a named allowance when the selection is open, and replace it once the actual product and delivery terms are known.

3. Sequence the work and handoffs

Confirm airflow design and duct routes before cutting openings. Show which task depends on access, a selected product or another trade. If that dependency is still open, label the price preliminary and identify the information needed before a firm quote.

Plan the handoffs: Confirm airflow design and duct routes before cutting openings. State which stage needs access or inspection before the next can begin, especially if a concealed condition might stop the work.

4. Set a change boundary

Concealed route conflicts or inadequate plant space change layout and labour. The example excludes whole-house retrofit, structural openings or unreviewed regulatory certification. Record the discovery, agree the revised work and update the estimate before adding it to the job.

Change trigger: Concealed route conflicts or inadequate plant space change layout and labour. If this happens, write down the revised quantity and responsibility before adding an item to the customer estimate.

Worked project calculation

The paired PDF has 7 cost lines. For example, Duct and insulation allowance is 54.9 metres × £47.20 = £2,591.28; Supply and extract terminals is 6 each × £108.00 = £648.00. Each amount is the stated quantity multiplied by its unit rate. Recheck whether a line describes installed work, a material purchase allowance or a distinct visit before changing its quantity.

Heat recovery ventilation installation example — GBP, fictional inputs
Work itemQuantityUnit rateAmount
Ventilation design allowance1 lump sum£520.00£520.00
HRV unit allowance1 each£2,080.00£2,080.00
Duct and insulation allowance54.9 metres£47.20£2,591.28
Supply and extract terminals6 each£108.00£648.00
Duct installation labour30 hours£76.00£2,280.00
Power and control allowance1 lump sum£576.00£576.00
Airflow balance and handoff1 lump sum£448.00£448.00
Illustrative total£9,143.28

Adding the 7 exact line amounts gives £9,143.28. The PDF uses a 0% tax input and no markup solely to display this arithmetic. Decide the appropriate tax, overhead and profit treatment for an actual job; the fictional rates are not local averages or price recommendations.

Scope and price boundaries

Install a selected heat-recovery ventilation unit with defined supply and extract points in an accessible area, subject to system design.

Outside this example: No whole-house retrofit, structural openings or unreviewed regulatory certification.

The role in this brief is mechanical contractor. Confirm who supplies the selected products, makes the site safe, removes waste and signs off the work. Where opening up reveals a different condition, document it and issue a revised scope and price rather than silently extending the base estimate. Also check access, drying or curing time, and the client handoff described in the work sequence.

Before you send

  • Count terminals, measure duct routes and available plant space, and record condensate and power needs.
  • Separate unit, duct, terminals and controls from commissioning.
  • Confirm airflow design and duct routes before cutting openings.
  • Concealed route conflicts or inadequate plant space change layout and labour.

Compare the written scope with every line in the heat recovery ventilation installation PDF example. The preview below is the first page of the actual app export; open the PDF to inspect its full scope, notes and amounts.

First page of a fictional heat recovery ventilation installation estimate PDF

Questions about this job

Which quantity controls this heat recovery ventilation installation estimate?

Count terminals, measure duct routes and available plant space, and record condensate and power needs.

When should this heat recovery ventilation installation quote be revised?

Concealed route conflicts or inadequate plant space change layout and labour. No whole-house retrofit, structural openings or unreviewed regulatory certification.

FROM SITE NOTES TO AN ITEMISED PDF

Build your own heat recovery ventilation installation estimate

Enter the project boundary and your measured lines in Estimates on iPhone or Android. Edit the fictional quantities and rates, add the actual business and client details, then inspect the PDF before sharing it.

Plain-text version · Browse all guides

Less paperwork. More time for the job.

Make your next estimate on iPhone or Android, then review it before sharing.

Download on the App StoreGet it on Google Play